Introduction
Fire safety is a critical aspect
of building design, especially in high-rise structures where emergency
evacuation can be challenging. One of the essential components of fire safety
systems is the Fireman Evacuation Lift (FEL), designed to assist
firefighters and occupants during emergencies. As per the Chief Fire
Officer (CFO) norms, these lifts must adhere to strict safety and
operational standards to ensure reliability during fire incidents.
At Aditya Engineering,
we specialize in designing and installing Fireman
Evacuation Lift as per
CFO norms, ensuring maximum safety and efficiency. Our solutions
are tailored to meet regulatory requirements while providing seamless
integration with building fire safety systems.
What is a Fireman Evacuation Lift?
A Fireman Evacuation Lift (FEL) is a specially designed
elevator that remains operational during fire emergencies, allowing
firefighters to access different floors safely and assisting in the evacuation
of occupants. Unlike standard lifts, which shut down during fires, FELs are
equipped with fire-resistant materials, emergency power backup, and advanced
control systems to function under extreme conditions.
Key Features of Fireman Evacuation Lifts:
- Fire-Resistant Construction – Built with
flame-retardant materials to withstand high temperatures.
- Emergency Power Supply – Equipped with backup
power to ensure continuous operation during power failures.
- Smoke Protection – Sealed doorss and
ventilation systems to prevent smoke ingress.
- Priority Control – Firefighters can
override normal operations to take control during emergencies.
- Communication Systems – Two-way
communication for coordination with emergency responders.
CFO Norms for Fireman Evacuation Lifts
The Chief Fire Officer (CFO) norms outline specific requirements
for Fireman Evacuation Lifts to ensure they meet safety and performance
standards. Compliance with these norms is mandatory for high-rise buildings,
commercial complexes, hospitals, and other public structures.
Key CFO Norms for Fireman Evacuation Lifts:
1. Design and Construction Requirements
- The lift must have a minimum load capacity of 1000 kg (or as specified by
local fire codes).
- The lift car and doors should be constructed
with fire-resistant materials capable
of withstanding high temperatures for at least 2 hours.
- The lift shaft must be pressurized to prevent smoke
entry.
2. Power Supply and Backup
- The lift must be connected to an emergency power source (generator
or UPS) to ensure operation during power outages.
- The backup power should support at least 90 minutes of continuous operation.
3. Control and Operation
- The lift must have a fireman’s override switch (Phase
I & Phase II operation) to allow firefighters to take control.
- Phase I Operation – Automatic recall of
the lift to the ground floor when a fire alarm is activated.
- Phase II Operation – Manual control by
firefighters to access specific floors during emergencies.
4. Safety and Communication Systems
- Two-way communication between the lift car
and the fire command center.
- Emergency lighting and alarms inside the
lift car.
- Smoke and heat detectors installed in the lift
lobby and shaft.
5. Testing and Maintenance
- Regular fire drills and lift testing must be conducted to ensure
compliance.
- Maintenance logs should be maintained as
per National Building Code
(NBC) and local fire safety regulations.
Why Choose Aditya Engineering for Fireman
Evacuation Lifts?
At Aditya Engineering,
we provide CFO-compliant Fireman
Evacuation Lifts that meet the highest safety standards. Our
expertise includes:
✔ Customized Solutions – Tailored to building
requirements and fire safety norms.
✔ Quality Assurance – Use of
fire-resistant materials and advanced safety mechanisms.
✔ Regulatory Compliance – Full
adherence to CFO norms, NBC, and IS codes.
✔ Installation & Maintenance –
End-to-end services from design to post-installation support.
Applications of Fireman Evacuation Lifts
Fireman Evacuation Lifts are
essential in various buildings, including:
- High-Rise Residential & Commercial
Buildings
- Hospitals & Healthcare Facilities
- Shopping Malls & Multiplexes
- Airports & Metro Stations
- Industrial Facilities & Warehouses
Conclusion
A Fireman
Evacuation Lift as per
CFO norms, is a vital component of modern fire safety systems,
ensuring safe evacuation and firefighting operations during emergencies.
Compliance with CFO norms is
crucial to guarantee reliability and performance.
Aditya
Engineering offers CFO-compliant Fireman Evacuation Lifts with
cutting-edge technology and robust safety features. Our solutions are designed
to protect lives and property while meeting all regulatory standards.
For expert consultation and
installation, contact us today:
📞 Call: +91-9870270602
📧 Email: adi_kk@ymail.com
🏢 Address: 6 Savitri Centre
Shastri Mall, Nana Chowk, Tardeo Mumbai 400007
🌐 Website: http://www.adityaeng.in
Ensure your building is fire-safe
with Aditya Engineering’s certified
Fireman Evacuation Lifts.